Healthcare

Patient Room

Healing environments should promote caregiver effectiveness and cleanability, but also patient wellbeing. Visually comfortable lighting with a pleasing aesthetic. Natural 24-hour sequence of light and dark, better sleep quality, personal lighting control.

Patient rooms require versatile lighting to meet the needs of both patients and staff..on their backs so lighting needs to be particularity comfortable. Staff need adequate lighting for various tasks to provide optimal patient care. This necessitates a range of lighting options, including ambient, exam, steplight, and task lighting, as well as personalized controls for patient comfort. Additionally, customizable solutions like white light and color tuning support circadian rhythms for improved well-being.

Lighting with Recommended Practice

DOWNLOAD ILLUMINANCE CHARTS

To convert lux to foot candles, divide lux value by 10.7 Illuminance levels listed in the charts above represent recommended industry standards for ages ranging from 25 to > 65.

TaskNotesHorizontal (Eh)Vertical (Ev)Avg:min
Ambient
Eh at floor – to cover 3ft border surrounding bed
100-2004 to 1

Ev at 5′ AFF*
20-40


Still looking for answers?

Whether you need information about shipping, installation, or pricing, or have questions about products, the Axis team is here to help with expert guidance and reliable service.

Photometric Scale Tool

Information

For Linears – Target Total Luminaire Lumens, calculate by multiplying the original length by your desired lumen value. For example, if you want 800 lumens, multiply 800 × 4 (original length). Target Total Luminaire Lumens input would be 3200.

For optimal accuracy, always use a maximum length of 4ft. Anything beyond this includes only one light source. Note: Direct/Indirect scales proportionally and cannot be adjusted separately.